The amplifier is CE approved and has 2 years warranty.


A800X

Download documentation:

Manual (pdf)


Similar products:

One channel - A800

Two channels - A800D

Phase inverter - A800DI

Same functionality but lower voltage - A400X

Faster - the amplifier can be adjusted for higher slew rate if the load is smaller than 200 pF. Please email your inquiry to info@flce.se

Special requirements - send email to info@flce.se

Back to selection table

Back to selection graph

High Voltage Linear Amplifier A800X

high-voltage linear amplifier F10A

This unit is a version of A800 amplifier equipped with two inputs, DC-offset and output atenuation.

Please see A800 page for technical details of the high voltage amplifier part.


Inputs

Input A is a normal non-inverting one. Using this input alone makes A800X functionally identical with A800 amplifier.

Input B can act as a inverting or non-inverting depending on the position of the corresponding switch.

Example

Applying different signals to both input results in their amplified sum or difference:

superposition of inputs

A800X oscilloscope example


DC offset

A DC level, adjustable within 0...+10V range, is provided on the front panel from two BNC contacts marked “OFFSET OUT”. Both contacts are internally connected to simplify monitoring of the output. For bipolar operation the DC level should be supplied to ±B input. Please note that the maximum total amplitude of superposed A and B signals should stay within ±4V range, otherwise clipping will occur.

Output attenuation

By means of dedicated switch the output can be attenuated 100 times (-40dB) for safe handling.